Article

High-Resolution Flaw Detection Using Eddy Current Probe Array Based on Giant Magnetoresistance Sensors

Year 2024 Journal / Conference IEEE Transactions on Magnetics NAFOSTED 2025 vol. 60, no. 9, pp. 1-5 DOI / Link https://doi.org/10.1109/tmag.2024.3402331 ↗

Authors

Long-Vu Bui ; Jen-Tzong Jeng ; Hua-Chih Huang ; Huu-Thang Nguyen ; Van-Dong Doan ; Truong-Han Nguyen ; Yu-Ju Lin

Abstract

This work presents a flaw detection system consisting of an array of eddy-current (EC) probes based on giant-magnetoresistance (GMR) sensors for mapping the defects on a metal sheet. Before measurement, a spatially dependent calibration process was done to compensate for the inter-channel inconsistency in output offsets and responsivity. The calibrated 8-channel probe array exhibits high sensitivity in revealing tiny features of defects with superior spatial resolution. The proposed system allows for the visualization of the geometric characteristics of the surface defects with an inter-spacing of more than 2 mm. The suggested approach has great potential in the nondestructive testing of metallic sheets for the characterization of minor and intricately shaped flaws.

Suggested keywords

eddy current testing giant magnetoresistive sensors defect detection defect mapping non-destructive testing high spatial resolution

BibTeX

@article{ICTU2024_3452,
  author = {Long-Vu Bui and Jen-Tzong Jeng and Hua-Chih Huang and Huu-Thang Nguyen and Van-Dong Doan and Truong-Han Nguyen and Yu-Ju Lin},
  title = {{High-Resolution Flaw Detection Using Eddy Current Probe Array Based on Giant Magnetoresistance Sensors}},
  journal = {IEEE Transactions on Magnetics},
  year = {2024},
  volume = {60},
  number = {9},
  pages = {1-5},
  doi = {10.1109/tmag.2024.3402331},
  url = {https://doi.org/10.1109/tmag.2024.3402331}
}

Notes

Metadata source: public ORCID record. ICTU affiliation has not been independently verified.