Electrochemical Exfoliation-Driven Graphene/ITO Sensors Toward UA, DA, and AA Detection
Authors
Abstract
A simple and environmentally friendly method was employed to fabricate graphene-modified indium tin oxide electrochemical sensor (GP/ITO) using electrophoretic deposition. The resulting GP/ITO sensor exhibited significantly enhanced electrochemical performance toward the simultaneous detection of ascorbic acid (AA), dopamine (DA), and uric acid (UA) with low detection limits of 2.42 μM for AA, 0.69 μM for DA, and 0.65 μM for UA, along with high sensitivity and good selectivity, making it promising for practical biomedical applications. © The Author(s), under exclusive license to Springer Nature Switzerland AG 2026.
Keywords
Ascorbic acid
Dopamine
Electrochemical sensor
Electrophoretic
Graphene
Uric acid
BibTeX
@inproceedings{ICTU2026_2417,
author = {Trinh Ngoc Hien and Dang Van Thanh and Ng uyen Xuan Hoa and Nguyen Van Dang and Nguyen Quoc Dung},
title = {{Electrochemical Exfoliation-Driven Graphene/ITO Sensors Toward UA, DA, and AA Detection}},
booktitle = {Lecture Notes in Networks and Systems},
year = {2026},
month = {5},
volume = {1804 LNNS},
pages = {198-205},
doi = {10.1007/978-3-032-15839-0_22},
url = {https://doi.org/10.1007/978-3-032-15839-0_22}
}